Περιγραφή
|
MODEL |
S-200-48 |
|
DC VOLTAGE |
48V |
|
CURRENT RANGE |
0~4.2A |
|
EFFICIENCY |
86% |
|
WAVE & NOISE |
200mVp-p |
|
ADJUSTABLE RANGE FOR DC VOLTAGE |
±10% |
|
LINE REGULATION |
±0.5% |
|
LOAD REGULATION |
±0.5% |
|
SETUP, RISE HOLD UP TIME |
200ms, 50ms,20ms/230VAC at full load |
|
VOLTAGE RANGE |
90 ~ 132VAC/180-264VAC by switch 254 ~ 370VDC |
|
FREQUENCY RANGE |
47 ~ 63Hz |
|
IMPACT CURRENT |
Cold start current 30A/115VAC 60A/230VAC |
|
WORKING TEMP. |
-10 ~ +50ºC |
|
OVERLOAD PROTECTION |
105%-150% cut off the output , automatic recovery |
|
OVER VOLTAGE PROTECTION |
105%-150% shunt down O/P voltage,re-power on to recover |
|
WITHSTAND VOLTAGE |
I/P-O/P:1.5KV I/P-FG:1.5KV O/P-FG:0.5KV 1minute |
|
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:500VDC/100M Ohms |
|
DIMENSION |
199*110*50mm (L*W*H) |
|
WERIGHT |
0.9kg |
|
PACKING |
42*31.5*26cm/20pcs/18Kg |
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25oCof ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC |
|